Description
- Reduced dimensions for easy mounting even with limited space
for installation. - Available with electromechanical or magnetic limit switch system (MAG versions).
- Ground fixing plate adjustable in height for accurate and simply installation.
- Suitable for domestic or multi-users gates.
- 24V version for automatic opening even in case of power failure
| Power supply | V | 230V ~ 50Hz | |
| Absorption (Closer 5) | A | 1.2 – 1.7A | |
| Absorption (Closer 8) | A | 1.2 – 2A | |
| Absorption (Closer 15) | A | 3A | |
| Power (Closer 5) | W | 250 W | |
| Power (Closer 8) | W | 300 W | |
| Power (Closer 15) | W | 600 W | |
| Condenser (Closer 5) | μF | 8 μF | |
| Condenser (Closer 8) | μF | 10 μF | |
| Condenser (Closer 15) | μF | 20 μF | |
| Thermal protection | °C | 150°C | |
| Maximum thrust (Closer 5) | N | 350 N | |
| Maximum thrust (Closer 8) | N | 440 N | |
| Maximum thrust (Closer 15) | N | 1000 N | |
| IP protection | IP | IP44 | |
| Engine revolutions (Closer 5/8/15) | g/m | 1400 | |
| Opening speed | m/min | 8.5 m/min | |
| Maximum door weight(Closer 5) | Kg | 500Kg | |
| Maximum door weight (Closer 8) | Kg | 800Kg | |
| Maximum door weight (Closer 15) | Kg |
|
|
| Duty cycle | % | 40% | |
| Power supply | V | 24V dc |
| Absorption | A | 0.7-10A |
| Power | W | 80 W |
| Condenser | μF | – |
| Thermal protection | °C | – |
| Maximum thrust | N | 500 N |
| IP protection | IP | IP44 |
| Engine revolutions | g/m | 1600 |
| Opening speed | m/min | 5-9 m/min |
| Maximum door weight | Kg | 650Kg |
| Duty cycle | % | 80% |
| Power supply | V | 115V ~ 60Hz |
| Absorption (Closer 5) | A | 2.0 – 2.3A |
| Absorption (Closer 8) | A | 2.8 – 3.2A |
| Absorption (Closer 15) | A | 6.4 – 6.6A |
| Power (Closer 5) | W | 280 W |
| Power (Closer 8) | W | 330 W |
| Power (Closer 15) | W | 600 W |
| Condenser (Closer 5/8) | μF | 30 μF |
| Condenser (Closer 15) | μF | 60 μF |
| Thermal protection | °C | 150°C |
| Maximum thrust (Closer 5) | N | 380 N |
| Maximum thrust (Closer 8) | N | 460 N |
| Maximum thrust (Closer 15) | N | 1000 N |
| IP protection | IP | IP44 |
| Engine revolutions | g/m | 1700 |
| Opening speed | m/min | 11 m/min |
| Maximum door weight (Closer 5) | Kg | 500Kg |
| Maximum door weight (Closer 8) | Kg | 800Kg |
| Maximum door weight (Closer 15) | Kg | 1500Kg |
| Duty cycle | % | 40% |